Download PDF by American National Standards Institute, Ieee Power: IEEE Std 666-1991, IEEE Design Guide for Electric Power

By American National Standards Institute, Ieee Power Engineering Society

ISBN-10: 1559375930

ISBN-13: 9781559375931

Show description

Read Online or Download IEEE Std 666-1991, IEEE Design Guide for Electric Power Service Systems for Generating Stations PDF

Best electrical & electronics books

Newnes Audio and Hi-Fi Engineer's Pocket Book by Vivian Capel PDF

A concise selection of useful and proper information for a person engaged on sound platforms. the themes lined comprise microphones, gramophones, compact discs, tape recording, top of the range radio, amplifiers, loudspeakers and public deal with platforms. New advancements which are coated within the moment version comprise electronic Audio Tape (DAT), the Philips electronic Compact Cassette (DCC), boundary area microphones and the LISCA public-address loudspeaker method.

Read e-book online Aperture antennas and diffraction theory PDF

Replacement equipment of aperture antenna research are defined during this ebook. The establishment of Engineering and know-how is likely one of the world's top specialist societies for the engineering and know-how group. The IET publishes greater than a hundred new titles each year; a wealthy mixture of books, journals and magazines with a again catalogue of greater than 350 books in 18 assorted topic parts together with: -Power & power -Renewable power -Radar, Sonar & Navigation -Electromagnetics -Electrical size -History of expertise -Technology administration

Extra resources for IEEE Std 666-1991, IEEE Design Guide for Electric Power Service Systems for Generating Stations

Sample text

During the reacceleration time after bus reconnection, all motors may be drawing close to locked rotor current and depressing the motor terminal voltages below motor nameplate requirements. In some cases, it may be required to load shed selected motors to ensure that total motor reacceleration requirements are not excessive. , opening of starter and relay contacts). This scheme is advantageous for undervoltage conditions on the normal bus caused by generator or turbine trips. If the undervoltage affected the alternative source, normal voltage should be restored by the time transfer is made.

13-1977 (R 1989), American National Standard for Rotating Electrical Machinery Ñ Cylindrical Rotor Synchronous Generators. 00-1987, IEEE Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers (ANSI). [B4] IEEE Std 100-1988, IEEE Standard Dictionary of Electrical and Electronics Terms (ANSI). [B5] IEEE Std 141-1986, IEEE Recommended Practice for Electric Power Distribution for Industrial Plants (ANSI). [B6] IEEE Standard 505-1977, IEEE Standard Nomenclature for Generating Station Electric Power Systems (ANSI).

A disadvantage is that the transfer time could exceed the safe Òdead-busÓ period of approximately 9 to 10 c. The delay times included in the relay protection design should be reviewed to ensure their adequacy for the transfer scheme selected. 1. The transfer is automatically initiated by the generator lock-out relay that closes the alternative source breaker, momentarily paralleling the alternative and normal source. An auxiliary ÒaÓ contact on this closed breaker will then trip the normal source breaker.

Download PDF sample

IEEE Std 666-1991, IEEE Design Guide for Electric Power Service Systems for Generating Stations by American National Standards Institute, Ieee Power Engineering Society